Instructions for Swarf Jar Kit

3D Printed Swarf Jar Kit for Air Pump

Steps to fit the base adapter, seal the pump correctly, and get the best performance from your swarf collection setup.

Tools & materials

  • Phillips-head screwdriver with a long shaft so you can reach the mounting screw once the adapter is in place
  • Silicone sealant — e.g. Selleys / Sika Silicone Sealant or a similar aquarium - or gasket-grade product suitable for your pump environment
  • Small container for the original screw and washer
  • Optional extra washer if the stock screw feels too loose when test-fitting the base adapter

Installation procedure

  1. Remove the stock top cover. You may need to pop off a small cap or cover first to expose the mounting screw.
  2. Keep the original screw and washer safe. You will reuse them to attach the base adapter.
  3. Note how the rubber gasket sits, then carefully remove it and set it aside. You will refit it in the same orientation.
  4. Remove any wadding packed around the opening.
  5. Refit the rubber gasket on the pump, lining it up so it covers all edges evenly.
  6. Dry-fit the base adapter: line it up with the screw hole and check clearance all around the pump. Confirm the stock screw (and washer) will draw the adapter down firmly — not loose. Add a washer only if needed. Do not overtighten during this test. Remove the base adapter and set it aside when satisfied.
  7. Apply sealant: run a continuous bead around the gasket edge where the base adapter will mate. Use enough to seal the joint when compressed, but keep sealant on the edge only — avoid excess that could fall into the pump cavity.
  8. Start the screw in the base adapter using the long shaft Phillips screwdriver. Hold light pressure on the tool so the screw stays seated in the adapter.
  9. Position the base adapter on the pump with light, even pressure so the sealant spreads uniformly. Drive the screw home to secure the adapter. Again, snug only — do not overtighten.
  10. Allow the sealant to cure per the manufacturer’s instructions (typically 24–48 hours) before running the pump under load.
Important Keep sealant out of the pump interior. A clean edge bead gives a reliable seal without blocking airflow paths.

Using the swarf jar

  • The top swarf jar adapter is removable. Fit it when needed; between clean-outs you can remove only the jar.
  • The jar does not need to be forced tightly onto the base. Suction from the pump holds it firmly in place.
  • Empty the swarf jar regularly to avoid pressure loss from a full or restricted chamber.

Alternative layout

You can also keep the full air pump assembly on the floor (or another spot away from the bed), and route vacuum to a swarf jar mounted elsewhere.

  • Leave the base adapter fitted to the pump as normal; use the top swarf jar adapter as the hose connection point on the pump side.
  • Connect a wider vacuum hose from that top adapter to your chip jar, which sits near the lathe.
  • Secure the hose so it does not snag or crush; avoid sharp bends that restrict airflow.
  • Use hose sizing that matches the adapter inlet — for larger vacuum line, fit on the outer wall of the inlet as described in the tubing section below.

Tubing

Supplied hose dimensions:

  • Outside diameter: 10 mm
  • Inside diameter: 8 mm

This size is intended to fit on the inner wall of the inlet. If you use larger tubing, remove the supplied liner/tube and fit your hose on the outer wall of the inlet instead.

 

Mounting & vibration

  • Mount the air pump on a separate base from the lathe to reduce vibration transfer.
  • Keep tubing from resting against or touching the pump body (e.g. along the sides). Contact can transmit vibration into the line and affect stability or noise.